【#2020】 o_chkp Spindle orientation completion check during second reference position
return
Set the distance from the second reference position to the position for checking that the spindle
orientation has completed during second reference position return.
When the set value is "0", the above check will be omitted.
---Setting range---
0 to 99999.999 (mm)
【#2021】 out_f Maximum speed outside soft limit range
Set the maximum speed outside the soft limit range.
---Setting range---
0 to 1000000 (mm/min)
【#2022】 G30SLX Validate soft limit (automatic and manual)
Select whether to disable a soft limit check during the second to the fourth reference position return
in both automatic and manual operation modes.
0: Enable
1: Disable
【#2023】 ozfmin Set up ATC speed lower limit
Set the minimum speed outside the soft limit range during the second to the fourth reference position
return.
---Setting range---
0 to 1000000 (mm/min)
【#2024】 synerr Allowable error
Set the maximum synchronization error, allowable at the synchronization error check, for the primary
axis.
When "0" is set, the error check will not be carried out.
---Setting range---
0 to 99999.999 (mm)
【#2025】 G28rap G28 rapid traverse rate
Set a rapid traverse rate for the dog type reference position return command.
This is not used for the distance-coded reference position detection.
---Setting range---
1 to 1000000 (mm/min)
【#2026】 G28crp G28 approach speed
Set the approach speed to the reference position.
(Note) The G28 approach speed unit is (10°/min) only when using the Z-phase type encoder (#1226
---Setting range---
1 to 60000 (mm/min)
aux10/bit3=1) for the spindle/C-axis reference position return type. The same unit is used for
both the micrometric and sub-micrometric specifications.