Stored Stroke Limit Ib - Mitsubishi Electric M700VS Series Setup Manual

Mitsubishi cnc
Table of Contents

Advertisement

8.2.2.3 Stored Stroke Limit IB

The boundary is set for each axis with the axis parameters "#2061 OT_1B-" and "#2062 OT_1B+". The inside of the set
boundary is the prohibited range.
3
(C)
4
2
: Moveable range
: Prohibited range
Point 5: "#2062 OT_1B+ (Soft limit IB+)" and
Point 6: "#2061 OT_1B- (Soft limit IB-)" are set with the coordinate values in the basic machine
coordinate system.
(A): Set value for (-) side
(B): Set value for (+) side
(C): Prohibited range by stored stroke limit II
(D): Prohibited range by stored stroke limit IB
Points 1 and 2 are the prohibited range set with stored stroke limit I.
Points 3 and 4 are the prohibited range set with stored stroke limit IIB.
5
(D)
6
(A)
(B)
M700VS Series Setup Manual
8.2 Stored stroke limit (S/W OT)
1
101