Device No. Assignment - Mitsubishi Electric M700VS Series Setup Manual

Mitsubishi cnc
Table of Contents

Advertisement

MITSUBISHI CNC
2 Connecting and Setting the Hardware

2.4.4 Device No. Assignment

The devices used by the PLC are determined as follows after the station Nos. are set with the rotary switches.
Rotary switch No.
0
1
2
3
4
5
6
7
Rotary switch No.
0
1
2
3
4
5
6
7
Rotary switch No.
0
1
2
3
4
5
6
7
The values shown in parentheses are the device range of the card mounted to the right side of the unit.
32
Device No. read in
RIO channel 1
X00 to X1F
X20 to X3F
X40 to X5F
X60 to X7F
X80 to X9F
XA0 to XBF
XC0 to XDF
XE0 to XFF
Device No. read in
RIO channel 2
X100 to X11F
X120 to X13F
X140 to X15F
X160 to X17F
X180 to X19F
X1A0 to X1BF
Y1A0 to Y1BF(Y1AF)
X1C0 to X1DF
Y1C0 to Y1DF(Y1CF)
X1E0 to X1FF
Y1E0 to Y1FF(Y1EF)
Device No. read in
RIO channel 3
-
-
X240 to X25F
X260 to X27F
X280 to X29F
X2A0 to X2BF
Y2A0 to Y2BF(Y2AF)
-
-
Output device No.
RIO channel 1
Y00 to Y1F(Y0F)
Y20 to Y3F(Y2F)
Y40 to Y5F(Y4F)
The rotary switches
Y60 to Y7F(Y6F)
correspond to the file
registers R200 to R207 in
Y80 to Y9F(Y8F)
order of small numbers.
YA0 to YBF(YAF)
YC0 to YDF(YCF)
YE0 to YFF(YEF)
Output device No.
RIO channel 2
Y100 to Y11F(Y10F)
Y120 to Y13F(Y12F)
Y140 to Y15F(Y14F)
Y160 to Y17F(Y16F)
Not possible (Neither input
nor output is possible)
Y180 to Y19F(Y18F)
Output device No.
RIO channel 3
-
-
Y240 to Y25F(Y24F)
Y260 to Y27F(Y26F)
Not possible (Neither input
nor output is possible)
Y280 to Y29F(Y28F)
-
-
Analog output (AO)
RIO channel 1
Analog output (AO)
RIO channel 2
Analog output (AO)
RIO channel 3

Hide quick links:

Advertisement

Table of Contents
loading