Appendix 1 Explanation of Parameters
【#24004+40(n-1)】 SLn PLC stop set Setting at PLC STOP
Set whether to refresh or compulsorily clear the slave stations at PLC STOP.
"n" represents the expansion slot No.(n=1 to 3)
0: Refresh
1: Compulsorily clear
(Note) Refer to "CC-Link System Master/Local Module User's Manual (SH(NA)-080394E-E)" for the
---Master station---
Set to "0" or "1".
---Local/standby master station---
Set to "0" or "1".
【#24005+40(n-1)(PR)】 SLn occ stations Number of occupied stations
Set the number of occupied local and standby master stations.
"n" represents the expansion slot No.(n=1 to 3)
---Master station---
Set to "0".
---Local/standby master station---
Set to either of "1" to "4".
---Setting range---
0 to 4
【#24006+40(n-1)(PR)】 SLn extended cyc Extended cyclic setting
Set the magnification for the extended cyclic operation of the local station whose type corresponds
to Ver.2.
"n" represents the expansion slot No.(n=1 to 3)
Set "1" for the local station whose type corresponds to Ver.1.
This function is out of specifications when the protocol version is Ver.1. The setting for the local
station is fixed to "1".
---Master station---
Set to "0".
---Local/standby master station---
Set to either of "1", "2", "4" or "8".
---Setting range---
0,1,2,4,8 (fold)
【#24007+40(n-1)】 SLn conn modules Number of connected modules
Set the total number of remote stations, local stations, intelligent device stations, standby master
station and reserved stations connected to the master station.
"n" represents the expansion slot No.(n=1 to 3)
---Master station---
Set to either of "1" to "64".
---Local/standby master station---
Set to "0".
---Setting range---
0 to 64 (modules)
【#24008+40(n-1)】 SLn num of retries Number of retries
Set the number of retries for when a communication error occurs.
"n" represents the expansion slot No.(n=1 to 3)
---Master station---
Set to either of "1" or "7".
---Local/standby master station---
Set to "0".
---Setting range---
0 to 7 (times)