Appendix 2.7 Distance-Coded Reference Scale Errors (Z8*) - Mitsubishi Electric M700VS Series Setup Manual

Mitsubishi cnc
Table of Contents

Advertisement

Appendix 2.7 Distance-coded Reference Scale Errors (Z8*)

Z80 Basic position lost 0001
Details
The basic point data saved in the NC has been damaged.
Remedy
- Set the parameters. If the basic point data is not restored by setting the parameters, perform zero
point initialization.
Z80 Basic position restore 0002
Details
The basic point data has been restored by setting the parameters.
Remedy
- Turn the power ON again to start the operation.
Z80 No spec: Distance-coded scale 0003
Details
The distance-coded reference scale has been set available although this function is out of the
specifications.
Remedy
- Check the specifications.
- If you do not use this function, correct the detector type with the servo parameter.
Z81 R-pos adjustment data lost 0001
Details
Reference position adjustment value data saved in the NC has been damaged.
Remedy
- Set the parameter. If the data is not restored by setting the parameter, establish the reference
position again.
Z81 R-pos adjustment data restored 0002
Details
After the 'Z81 R-pos adjustment data lost 0001', the data has been recovered by setting the parameter.
Remedy
- Establish the reference position to start the operation.
Appendix 2.7 Distance-coded Reference Scale Errors (Z8*)
M700VS Series Setup Manual
565