Mitsubishi Electric M700VS Series Setup Manual page 363

Mitsubishi cnc
Table of Contents

Advertisement

MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#2310】 SV110
Not used. Set to "0".
【#2311】 SV111
Not used. Set to "0".
【#2312】 SV112
Not used. Set to "0".
【#2313】 SV113 SSF8 Servo function 8
Select the servo functions.
A function is assigned to each bit.
Set this in hexadecimal format.
bit F : ssc Safety observation function
0: Stop
bit E-8 :
Not used. Set to "0".
bit 7 : nmerc Machine error compensation amount
When disabled, the machine error compensation amount including backlash and pitch error to be
compensated by an NC will be ignored by the servo control.
Use this to adjust the lost motion compensation by the electric end roundness measurement.
0: Normal setting
bit 6-0 :
Not used. Set to "0".
【#2314】 SV114 SSF9 Servo function 9
Select the servo functions.
A function is assigned to each bit.
Set this in hexadecimal format.
bit F-9 :
Not used. Set to "0".
bit 8 : nohis History of communication error alarm between NC and DRV (34, 36, 38, 39)
Set "1" for C70.
0: Enable
bit 7 : cse Command speed monitoring function
0: Normal setting
bit 6-0 :
Not used. Set to "0".
346
1: Start
1: Disable
1: Disable
1: Enable
nmerc
ssc
cse
nohis

Hide quick links: