(Note) When the analog output is equipped to several RIO channels, maximum of four RIO channels will be valid in the
following order of priority.
(1) RIO channel 1, (2) RIO channel 2, (3) RIO channel 3
(Ex.)
When the analog output is equipped to RIO channel 1 and RIO channel 3.
AO
AO
Fourth
Second
station
station
#3024 sout
2
3
4
5
The analog output R registers are allocated in ascending order of channels and station
CAUTION
numbers automatically. Therefore, the analog output destination may change depending on
the added option.
RIO1
Control unit
RIO unit
R register
Allocation of AO
R200 (AO1)
2nd station of RIO 1
R201 (AO2)
4th station of RIO 1
R202 (AO3)
6th station of RIO 3
R203 (AO4)