Mitsubishi Electric M700VS Series Setup Manual page 320

Mitsubishi cnc
Table of Contents

Advertisement

【#2073】 zrn_dog Origin dog Random assignment device
Under the standard specifications, the origin dog signal is assigned to a fixed device. Set the input
device in this parameter when it is desired to assign the origin dog signal to a position other than the
fixed device.
(Note1) This parameter is enabled in the following conditions.
(Note 2) When this parameter is valid, do not set the existing device number. If the existing device
---Setting range---
0000 to 02FF (HEX)
【#2074】 H/W_OT+ H/W OT+ Random assignment device
Under the standard specifications, the OT (+) signal is assigned to a fixed device. Set the input
device in this parameter when it is desired to assign the OT (+) signal to a position other than the
fixed device.
(Note1) This parameter is enabled in the following conditions.
(Note 2) When this parameter is valid, do not set the existing device number. If the existing device
---Setting range---
0000 to 02FF (HEX)
【#2075】 H/W_OT- H/W OT- Random assignment device
Under the standard specifications, the OT (-) signal is assigned to a fixed device. Set the input
device in this parameter when it is desired to assign the OT (-) signal to a position other than the
fixed device.
(Note1) This parameter is enabled in the following conditions.
(Note 2) When this parameter is valid, do not set the existing device number. If the existing device
---Setting range---
0000 to 02FF (HEX)
【#2076】 index_x Index table indexing axis
Select whether the axis is a normal axis or an index table indexing axis.
0: Normal axis
1: Index table indexing axis
(Note) This parameter is valid only for the NC axis. The parameter is invalid if set for the PLC axis.
【#2077】 G0inps G0 in-position width
Set the in-position width for G0.
Between SV024 and this parameter, the parameter with a larger value will be applied.
When "0" is set, this parameter will be invalid: only SV024 will be available.
---Setting range---
0.000 to 99.999 (mm)
NC axis: When "#1226 aux10/bit5" is set to "1".
PLC axis: When "#1246 set18/bit7" is set to "1".
number is set, an emergency stop will occur. However, no device number check will be
performed for an axis to which the "near-point dog ignored" signal is input.
NC axis: When "#1226 aux10/bit5" is set to "1".
PLC axis: When "#1246 set18/bit7" is set to "1".
number is set, an emergency stop will occur. However, no device number check will be
performed for an axis to which the "OT ignored" signal is input.
NC axis: When "#1226 aux10/bit5" is set to "1".
PLC axis: When "#1246 set18/bit7" is set to "1".
number is set, an emergency stop will occur. However, no device number check will be
performed for an axis to which the "OT ignored" signal is input.
M700VS Series Setup Manual
Appendix 1.3 Axis Specifications Parameters
303