Mitsubishi Electric M700VS Series Setup Manual page 538

Mitsubishi cnc
Table of Contents

Advertisement

T03 Aux axis changeover error 0330
Details
The "NC axis control selection" signal was turned OFF while a NC axis was traveling.
Remedy
- Turn the "NC axis control selection" signal ON and press the CYCLE START switch to resume the
automatic operation.
T04 Collation stop 0401
Details
Collation stop occurred.
Remedy
- Execute the automatic start to resume the automatic operation.
T10 Fin wait (Factors for waiting completion)
Details
The following Nos. are shown during the operation of the corresponding completion wait factor. The
numbers will disappear when the operation is completed.
The completion wait factor is indicated with four digits (in hexadecimal).
Display format of completion wait factor
0__ __ __
(a)(b)(c)
Each of the hexadecimal numbers (a), (b) and (c) indicates the following details.
(a)
bit0: In dwell execution
bit3: Unclamp signal wait (Note 1)
(b)
bit0: Waiting for spindle position to be looped
bit3: Door open (Note 2)
(c)
bit0: Waiting for MSTB completion
bit1: Waiting for rapid traverse deceleration
bit2: Waiting for cutting speed deceleration
bit3: Waiting for spindle orientation completion
(Note 1) This shows the wait state for the unclamp signal's ON/OFF for the index table indexing.
(Note 2) This shows the door open state caused by the door interlock function.
T11 Fin wait 0010(Factors for waiting completion)
Details
The following Nos. are shown during the operation of the corresponding completion wait factor. The
numbers will disappear when the operation is completed.
The completion wait factor is indicated with four digits (in hexadecimal).
Display format of completion wait factor
0__ __ __
(a)(b)(c)
Each of the hexadecimal numbers (a), (b) and (c) indicates the following details.
bit0:Operation alarm display being postponed
Remedy
The parameter "#1342 AlmDly" may be able to postpone displaying a part of an operation alarm,
depending on the setting.
This stop code will remain displayed while any alarm is being postponed.
And it will disappear if the postponed alarm is displayed or canceled.