11 Data Backup and Restoration
The following two functions are available for the data backup and restoration: all backup function for files in batch and
input/output function for separate files.
The following devices are available in all backup and restoration.
M700VW Series: DS, Memory card (CF card or USB memory), and hard disk (HD)
M700VS Series: Memory card (CF card) and USB memory
Files to be backed up/ restored are as follows.
Screen display
System data
Ladder
APLC data
Custom data
(For M700VS only)
This manual explains the procedures of all backup using a CF card.
For the input/output function for separate files, refer to the Instruction Manual.

11.1 All Backup

(1) Carry out the emergency stop.
(2) Insert a CF card into the interface on front of display unit.
(Note)
When M700VW Series is used, an adapter is required to insert a CF card into the interface on front of
display unit.
(3) Enter the password on the Mainte screen.
(a) On the Mainte screen, select [Mainte] and then [Psswd input].
(b) Enter "MPARA" in the setting area and press the INPUT key.
(4) Press the cancel key to return to the Mainte screen. Select [Mainte] and then [All backup].
118
File name
SRAM data (binary files)
SRAM.BIN
Programs, parameters, R registers and so on
USERPLC.LAD
User PLC program
APLC.BIN
C language module created by user
Custom screen data (binary files)
CUSTOM.BIN
(Custom screen modules, setting files (Config.ini/
customdef.ini/customload.txt) and PLC alarm messages)
Data type