Mitsubishi Electric M700VS Series Setup Manual page 42

Mitsubishi cnc
Table of Contents

Advertisement

Bottom
(A)
(B)
(C)
(A) RIO1 (From controller)
(B) RIO2 (To terminating resister or to next RIO unit)
(C) DCIN (24VDC input)
Unit type
DX10* (FCUA-DX10*)
DX11* (FCUA-DX11*)
DX12* (FCUA-DX12*)
DX14* (FCUA-DX14*)
(Note)
"*" in the table is "0" when the output is sink type, and is "1" when the output is source type. The input is
changeable.
Machine control signals that can be
handled
Digital input signal (DI) (Photocoupler
insulation)
Digital output signal (DO) (Non-insulated)
Digital input signal (DI) (Photocoupler
insulation)
Digital output signal (DO) (Non-insulated)
Digital input signal (DI) (Photocoupler
insulation)
Digital output signal (DO) (Non-insulated)
Analog output (AO)
Digital input signal (DI) (Photocoupler
insulation)
Digital output signal (DO) (Non-insulated)
Analog input (AI)
Analog output (AO)
M700VS Series Setup Manual
2.4 Connecting and Setting the Remote I/O Unit
Left
Right
Total
32 points
-
32 points
32 points
-
32 points
32 points 32 points 64 points
32 points 16 points 48 points
32 points 32 points 64 points
32 points 16 points 48 points
-
1 point
1 point
32 points
-
32 points
32 points
-
32 points
-
4 points
4 points
-
1 point
1 point
Number of
occupied
stations
1
2
2
2
25

Hide quick links: