【#2171】 Lmc2QR Lost motion compensation gain 2 for high-speed retract
Set the lost motion compensation gain in drilling cycle at high-speed retract (CW: - to + direction,
CCW: + to - direction).
Set "-1" when drilling cycle at high-speed retract is not performed.
When set to "0", the performance will follow the setting of "#2170 Lmc1QR (Lost motion
compensation gain 1 for high-speed retract)".
---Setting range---
-1, 0 to 200(%)
【#2172】 LmcdQR Lost motion compensation timing for high-speed retract
Set the timing of the lost motion compensation in drilling cycle at high-speed retract.
When set to "0", the performance will follow the setting of "#2239 SV039 LMCD (Lost motion
compensation timing)".
---Setting range---
0 to 2000 (ms)
【#2173】 LmckQR Lost motion compensation 3 spring constant for high-speed retract
Set the machine system's spring constant when using lost motion compensation type 3 in drilling
cycle with high-speed retract.
When set to "0", the performance will follow the setting of "#2285 SV085 LMCk (Lost motion
compensation 3 spring constant)".
---Setting range---
0 to 32767(0.01%/μm)
【#2174】 LmccQR Lost motion compensation 3 viscous coefficient for high-speed retract
Set the machine system's viscous coefficient when using lost motion compensation type 3 in drilling
cycle at high-speed retract.
When set to "0", the performance will follow the setting of "#2286 SV086 LMCc (Lost motion
compensation 3 viscous coefficient)".
---Setting range---
0 to 32767(0.01%/μm)
【#2175】 Special Ax Radius
Set the radius of the special diametral axis.
---Setting range---
0 to 99999.999 (mm)
【#2176】 Special Ax Clamp
Set a clamp speed for the special diametral axis control.
---Setting range---
0 to 1000000 (°/min)
(Note)For "#2001 rapid" and "#2002 clamp", set speeds on a machining line.
【#2177】 ManualFeedBtL
Set the acceleration/deceleration time constant for manual feed rate B.
(Note)When set to "0", this parameter will not be used: conventional acceleration/deceleration will be
---Setting range---
0 to 40000 (ms)
Special diametral axis radius
Special diametral axis clamp speed
When the value in "#2176 Special Ax Clamp" is smaller than that in "#2001 rapid", "Special Ax
Clamp" value will be applied to the clamp speed.
Time constant for manual feed rate B