4 Setting the Parameters and Date/Time
(5) Write the parameter settings and format the system.
(a) Select [Param setting].
(b) The message "Set up parameter? (Y/N)" appears. Press "Y".
(c)
The message "Param set ended. Format NC memory? (Y/N)" appears. Press "Y".
(d) The message "Format complete" appears when the format is completed.
(6) Turn the power OFF and ON.
(Note)
When MDS-D-SVJ3/SPJ3 Series is used, the regenerative resistor type must be set with the servo parameter
"#2236 SV036" and the spindle parameter "#13032 SP032" in addition to the settings above.
52