Mitsubishi Electric M700VS Series Setup Manual page 473

Mitsubishi cnc
Table of Contents

Advertisement

MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#24122+15(m-1)】 CNm extended cyc Extended cyclic setting
Select the magnification for the extended cycling operation of the connected remote, local and
intelligent stations.
Set "1" when the protocol version is Ver.1.
Set "0" when no setting is required.
"m" means the m-th connected station in ascending order of station No. (m=1 to 64)
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set to "0".
---Setting range---
0,1,2,4,8 (times)
【#24123+15(m-1)】 CNm occ stations Number of occupied stations
Set the number of the occupied stations by the connected remote, local and intelligent stations.
Set 1 for 8 points I/O and 16 points I/O.
Set "0" when no setting is required.
"m" means the m-th connected station in ascending order of station No. (m= 1 to 64)
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set to "0".
---Setting range---
0 to 4 (stations occupied)
【#24124+15(m-1)】 CNm station No. Station No.
Set the station No. of the connected remote, local and intelligent stations.
Set "0" when no setting is required.
"m" means the m-th connected station in ascending order of station No. (m= 1 to 64)
---Master station---
Set a value within the setting range.
---Local/standby master station---
Set to "0".
---Setting range---
0 to 64