For rotary axis
Settings of dog1 and
dog2
dog1 < dog2
dog1 > dog2
dog1<=0 and 360<=dog2
Positions of dog1 and dog2
dog2
dog1
(Example)
dog1 = 30.000
dog2 = 330.000
dog1
dog2
(Example)
dog1 = - 30.000
dog2 = 30.000
dog1
dog2
(Example)
dog1 = 330.000
dog2 = 30.000
dog1
dog2
(Example)
dog1 = - 30.000
dog2 = 390.000
M700VS Series Setup Manual
Appendix 1.21 Position Switch (Function Details)
Description
A signal is output when the machine
reaches between dog1 and dog2.
Signal output is the same when
dog1 is negative.
A signal is output when the machine
reaches between dog2 and dog1.
When the range of dog1 and dog2
include 0 to 360 degrees, a signal is
output whenever and wherever the
machine reaches.
495