【#9104】 DEV0 PARITY CHECK
Select whether to add the parity check bit to the data.
ON
OFF
Start bit
Set this parameter in accordance with the I/O device specifications.
0: Not add a parity bit in I/O mode
1: Add a parity bit in I/O mode
【#9105】 DEV0 EVEN PARITY
Select odd or even when parity is added to the data. This parameter is ignored when no parity is
added.
0: Odd parity
1: Even parity
【#9106】 DEV0 CHR. LENGTH
Set the length of the data bit.
Refer to "#9104 DEV0 PARITY CHECK".
0: 5 (bit)
1: 6
2: 7 (NC connection not supported)
3: 8
【#9107】 DEV0 TERMINATR TYP
Select the code to terminate data reading.
0, 3: EOR
1, 2: EOB or EOR
[When M700/700VW display side serial port is selected]
0: No terminator
1: EOR
2: EOB
3: EOB or EOR
【#9108】 DEV0 HAND SHAKE
Select the transmission control method.
No handshaking will be used when a value except 1 to 3 is set.
1: RTS/CTS method
2: No handshaking
3: DC code method
【#9109】 DEV0 DC CODE PRTY
Select the DC code type when the DC code method is selected.
0: Not add parity to DC code (DC3 = 13H)
1: Add parity to DC code (DC3 = 93H)
【#9111】 DEV0 DC2/4 OUTPUT
Select the DC code handling when outputting data to the output device.
DC2 / DC4
0: None / None
1: Yes / None
2: None / Yes
3: Yes / Yes
【#9112】 DEV0 CR OUTPUT
Select whether to add the (CR) code just before the EOB (L/F) code during output.
0: Not add
1: Add
1character
b1 b2 b3 b4 b5 b6
bn
Data bit
Parity bit
M700VS Series Setup Manual
Appendix 1.1 User Parameters
Stop bit
187