Appendix 1 Explanation of Parameters
bit 7-0 : mtyp(HEX-2,1) Motor type
Set the motor type. Set this with SV017/bitF-C.
For SV017/bitF-C = 1 (200V standard motor series)
HF75
HF105
HF54
HF104
HF154
HF224
HF204
HF354
HF123
HF223
HF303
HF453
HF703
HF903
HF142
HF302
(Note 1) When MDS-DM-V3 is connected
(Note 2) When MDS-DM-V3 M/S axis is connected
(Note 3) MDS-D-SVJ3 only
For SV017/bitF-C = 3 (400V standard motor series)
HF-H75
HF-H105 : 02h,
HF-H54
HF-H104 : 04h,
HF-H154 : 05h,
HF-H204 : 07h,
HF-H354 : 08h,
HF-H453 : 09h,
HF-H703 : 0Ah
HF-H903 : 0Bh,
HC-H1502: B9h
For linear motor and direct-drive motor, follow the settings stated in respective materials.
【#2226】 SV026 OD2 Excessive error detection width during servo OFF
Set the excessive error detection width during servo OFF.
<Standard setting value>
OD1=OD2= (Rapid traverse rate [mm/min]) / (60×PGN1) / 2 [mm]
When set to "0", the excessive error alarm detection will be ignored.
Related parameters: SV023
---Setting range---
0 to 32767 (mm)
However, when SV084/bitC=1, the setting range is from 0 to 32767 (μm).
(Only for MDS-D/DH and MDS-DM)
326
: 01h
HP54
: 02h
HP104 : 12h
: 03h
HP154 : 13h
: 04h
HP224 : 1Bh
: 05h, 0Fh (Note 1)
HP204 : 14h
: 06h
HP354 : 15h
: 07h
HP454 : 16h
: 08h
HP704 : 17h
: 24h
HP903 : 18h
: 26h, 2Dh (Note 2)
HP1103 : 19h
: 28h
: 09h
: 0Ah
: 0Bh
: 25h
: 27h, 2Eh (Note 2)
: 01h,
HP-H54
HP-H104 : 12h
: 03h,
HP-H154 : 13h
HP-H204 : 14h
HP-H354 : 15h
HP-H454 : 16h
HP-H704 : 17h
HP-H903 : 18h
HP-H1103: 19h
HP-H224 : 1Bh
: 11h
HF-KP13 : E9h (Note 3)
HF-KP23 : EAh
HF-KP43 : EBh
HF-KP73 : ECh
: 11h