Appendix 1 Explanation of Parameters
【#1285(PR)】 ext21
bit0: Multi-part system program management
Select whether to use multi-part system program management.
0: Not use
1: Use
(Note) When this parameter's value is changed, the power must be turned OFF and ON, and the
bit1: Program search type switch
Select how to search a program to operate.
0: Operation search is performed in the selected part system.
1: Operation search is performed for all part systems. (The program No. will be common to all part
bit2: Multi-part system program generation and operation
Select whether to perform the following processes for all the part systems or for each part system
separately in multi-part system program management: newly create, delete or rename the machining
programs in NC memory (including MDI program and machine tool builder macro program) or
transfer, compare, merge the programs between NC memory and other device.
0: Perform these processes for the programs in all part systems. If no subprogram contents are
1: Perform these processes for the programs in the selected part system.
【#1286(PR)】 ext22
bit2: O No. for program input No.
Select the operation when the same program No. is input during data input.
0: The O No. is handled as a character string data.
1: The O No. is handled as a program No. Whether to overwrite the program or cause an error is
bit3: No O No. at machining program input
Select whether to enable the machining program input even if there is no program No. (O No.).
The program No. is fixed to 01 in this case.
0: Disable
1: Enable
bit5: Selection of multi-part system program input/output method
Select whether to perform the transfer from NC memory to other device for all the part systems or for
each part system separately in multi-part system program management.
0: Output the designated programs for all the part systems.
1: Output the programs of only the selected part system.
266
system formatted. Two or more part systems from [1] to [4] need to be set to "1" in "#1001
SYS_ON". Otherwise this parameter will be disabled even though set to "1".
systems.)
found by the subprogram call during automatic operation, the program will be searched for from
$1.
decided by "#1218 bit7 Input by program overwrite".