P390 No spec: Geometric
Details
A geometric command was issued though it is out of specifications.
Remedy
- Check the specifications.
P391 No spec: Geometric arc
Details
There are no geometric IB specifications.
Remedy
- Check the specifications.
P392 Angle < 1 degree (GEOMT)
Details
The angular difference between the geometric line and line is 1° or less.
Remedy
- Correct the geometric angle.
P393 Inc value in 2nd block (GEOMT)
Details
The second geometric block has a command with an incremental value.
Remedy
- Issue a command with an absolute value in the second geometric block.
P394 No linear move command (GEOMT)
Details
The second geometric block contains no linear command.
Remedy
- Issue the G01 command.
P395 Illegal address (GEOMT)
Details
The geometric format is invalid.
Remedy
- Correct the program.
P396 Plane selected in GEOMT ctrl
Details
A plane switching command was issued during geometric command processing.
Remedy
- Complete the plane switching command before geometric command processing.
P397 Arc error (GEOMT)
Details
In geometric IB, the circular arc end point does not contact or cross the next block start point.
Remedy
- Correct the geometric circular arc command and the preceding and following commands.
P398 No spec: Geometric1B
Details
A geometric command was issued though the geometric IB specifications are not provided.
Remedy
- Check the specifications.