Connection And Station No. Setting On Remote I/O Unit - Mitsubishi Electric M700VS Series Setup Manual

Mitsubishi cnc
Table of Contents

Advertisement

MITSUBISHI CNC
2 Connecting and Setting the Hardware

2.4.2 Connection and Station No. Setting on Remote I/O Unit

When connecting directly to the control unit
Control unit
FCU7-MU531/ FCU7-MU541/ FCU7-MA541
RIO1
CG72
(Note)
A remote I/O unit has one or two rotary switch(es) for unit No. setting, which links the device Nos. (with X/
Y). The rotary switch setting is as follows, from "0" to "7".
When using MITSUBISHI CNC Machine operation panel, RIO station No. "4" to "6" will be occupied.
26
Remote I/O 1ch
FCUA-R211/SH41
Remote I/O 2ch
G214
Station
Rotary switch
No.
1
0
2
1
3
2
4
3
5
4
6
5
7
6
8
7
Remote I/O unit
FCUA-DX1**
Station No.1 - 8
Max. 8 channels
Max. input: 256 points (X000 to X0FF)
Max. output: 256 points (Y000 to Y0FF)
FCUA-DX1**
Station No.1 - 8
Max. 8 channels
Max. input: 256 points (X100 to X1FF)
Max. output: 256 points (Y100 to Y1FF)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents