Mitsubishi Electric M700VS Series Setup Manual page 408

Mitsubishi cnc
Table of Contents

Advertisement

【#13114】 SP114 MKT Coil changeover gate cutoff timer
Set the time required to cut off the gate when turning OFF/ON the coil switch contactor.
The value should be longer than the coil switch contactor's OFF/ON time.
The standard setting is "150".
---Setting range---
0 to 3500 (ms)
【#13115】 SP115 MKT2 Coil changeover current limit timer
Set the time required to limit the current immediately after the coil switch contactor ON/OFF is
completed and the gate is turned ON.
The standard setting is "250".
---Setting range---
0 to 3500 (ms)
【#13116】 SP116 MKIL Coil changeover current limit value
Set the time required to limit the current immediately after the coil switch contactor ON/OFF is
completed and the gate is turned ON.
The standard setting is "120".
---Setting range---
0 to 999 (Short-time rated %)
【#13117】 SP117 SETM Excessive speed deviation timer
Set the time to detect the speed excessive error alarm.
Set the time required to the machine.
The standard setting is "12".
---Setting range---
0 to 60 (s)
【#13118(PR)】 SP118 MSFT Magnetic pole shift amount
Set the magnetic pole shift amount of IPM spindle motor.
During DC excitation of the initial setup: Set the same value displayed in the "AFLT gain" on the NC
monitor screen in SP225(SFNC5)/bit4(dcd)=1.
When not using, set to "0".
---Setting range---
-18000 to 18000 (electrical angle 0.01°)
【#13119】 SP119 FSP4 Notch filter specifications 4
When not using, set to "0".
Set the target attenuation and damping coefficient of the notch filter.
To determine the value, multiply the damping coefficient by 10000, and add it to the absolute value
of the target attenuation -dB.
The setting range of each coefficient is as follows.
Damping coefficient: 0.01 - 1.00 (Increment: 0.01)
When "0" is set, the actual value to be set is 1.00.
Target attenuation: -80db - -1db (Increment: 1dB)
When "0" is set, the actual value to be set is -80.
E.g.: When the target attenuation is -40dB, and damping coefficient is 1.00
1.00×10000 + ABS(-40) = 10040
---Setting range---
0 to 32767