Mitsubishi Electric M700VS Series Setup Manual page 207

Mitsubishi cnc
Table of Contents

Advertisement

MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#9201】 DEV1 DEVICE NAME
Set the device name corresponding to the device No.
Set a simple name for quick identification.
---Setting range---
Use alphabet characters, numerals and symbols to set a name within 3 characters.
【#9202】 DEV1 BAUD RATE
Select the serial communication speed.
0: 19200 (bps)
1: 9600
2: 4800
3: 2400
4: 1200
5: 600
6: 300
7: 110
【#9203】 DEV1 STOP BIT
Select the stop bit length used in the start-stop system.
Refer to "#9204 DEV1 PARITY CHECK". At the output of data, the number of characters is always
adjusted to for the parity check.
1: 1 (bit)
2: 1.5
3: 2
【#9204】 DEV1 PARITY CHECK
Select whether to add a parity check bit to the data.
ON
OFF
Start bit
Set this parameter in accordance with the I/O device specifications.
0: Not add a parity bit in I/O mode
1: Add a parity bit in I/O mode
【#9205】 DEV1 EVEN PARITY
Select whether even or odd parity will be used when parity is used. This parameter is ignored when
no parity is added.
0: Odd parity
1: Even parity
【#9206】 DEV1 CHR. LENGTH
Select the length of the data bit.
Refer to "#9204 DEV1 PARITY CHECK".
0: 5 (bit)
1: 6
2: 7 (NC connection not supported)
3: 8
【#9207】 DEV1 TERMINATR TYP
Select the code to terminate data reading.
0, 3: EOR
1, 2: EOB or EOR
[When M700/700VW display side serial port is selected]
0: No terminator
1: EOR
2: EOB
3: EOB or EOR