Mitsubishi Electric M700VS Series Setup Manual page 250

Mitsubishi cnc
Table of Contents

Advertisement

【#1135】 unt_nm Unit name
Set the unit name.
Set with 4 or less characters consisting of both alphabets and numbers.
If "0" is set, the unit name won't be displayed.
---Setting range---
4 or less characters consisting of both alphabets and numbers
【#1136】 optype
Not used. Set to "0".
【#1137】 Cntsel
Not used. Set to "0".
【#1138】 Pnosel
Not used. Set to "0".
【#1139】 edtype
Not used. Set to "0".
【#1140】 Mn100 M code number
Set the first number of M code that corresponds to the setup Nos. from 100 to 199.
---Setting range-
0 to 99999999
【#1141】 Mn200 M code number
Set the first number of M code that corresponds to the setup Nos. from 200 to 299.
---Setting range---
0 to 99999999
【#1142】 Mn300 M code number
Set the first number of M code that corresponds to the setup Nos. from 300 to 399.
---Setting range---
0 to 99999999
【#1143】 Mn400 M code number
Set the first number of M code that corresponds to the setup Nos. from 400 to 499.
---Setting range---
0 to 99999999
【#1144】 mdlkof MDI setup lock
Select whether to enable MDI setting in non-MDI mode.
0: Disable MDI setting
1: Enable MDI setting
【#1145】 I_abs Manual ABS parameter
Select how to handle the absolute position data during automatic handle interrupt.
0: Absolute position data will be renewed if manual ABS switch is ON. If it is OFF, data won't be
1: Follow the "intabs" state when "#1061 intabs" is enabled
renewed.