Bootload Mode Setting; Query The Operation Mode; Set The Operation Mode; Query The Mac Address Of The Device - Lightware UBEX Series User Manual

Matrix application mode, av over ip multimedia extender
Table of Contents

Advertisement

 
 
9. Programmer's Reference
9. Programmer's Reference
9.5.3. Bootload Mode Setting
The device can be set to bootload (service / firmware upgrade) mode. The AV signal transmission is
terminated in this mode.
Command and Response
#bootload
ç CALL•/SYS/ENDPOINTS/<UBEX_EP>:bootload()
æ mO•/SYS/ENDPOINTS/<UBEX_EP>:bootload=
Example
ç CALL /SYS/ENDPOINTS/UBEX0039A1:bootload()
æ mO /SYS/ENDPOINTS/UBEX0039A1:bootload=
9.5.4. Query the Operation Mode
Command and Response
#operationmode #transmitter #receiver #transceiver #tx #rx #trx
ç GET•/SYS/ENDPOINTS/<UBEX_EP>.OperationMode
pw•/SYS/ENDPOINTS/<UBEX_EP>.OperationMode=<operation_mode>
æ
Parameters
Identifier
Parameter description
The operation mode of
<operation_mode>
the endpoint device
Example
ç GET /SYS/ENDPOINTS/UBEX0039A1.OperationMode
æ pw /SYS/ENDPOINTS/UBEX0039A1.OperationMode=Transceiver
Applied F-series endpoint firmware package: v1.4.1 | Applied R-series endpoint firmware package: v1.4.1 | Applied MMU firmware package: v1.2.1 | LDC software: v1.34.0b2
UBEX series – Matrix Application Mode – User's Manual
UBEX series – Matrix Application Mode – User's Manual
Value
Explanation
The endpoint device operates as
Transmitter
a Transmitter. See the details in the
Transmitter Mode
section.
The endpoint device operates as
Receiver
a Receiver. See the details in the
Receiver Mode
section.
The endpoint device operates as
Transceiver
a Transceiver. See the details in the
Transceiver Mode
section.
9.5.5. Set the Operation Mode

ATTENTION!
This operation always requires rebooting the endpoint device!
INFO:

The setting is stored in the MMU.
The operation mode (transmitter, receiver, or transceiver) of the device can be changed based on the required
application.
Command and Response
SET•/SYS/ENDPOINTS/<UBEX_EP>.OperationMode=<operation_mode>
ç
pw•/SYS/ENDPOINTS/<UBEX_EP>.OperationMode=<operation_mode>
æ
Parameters
Identifier
Parameter description
The operation mode of
<operation_mode>
the endpoint device
Example
ç SET /SYS/ENDPOINTS/UBEX0039A1.OperationMode=Receiver
æ pw /SYS/ENDPOINTS/UBEX0039A1.OperationMode=Receiver
9.5.6. Query the MAC Address of the Device
Command and Response
#mac
ç GET•/SYS/ENDPOINTS/<UBEX_EP>.MacAddress
pr•/SYS/ENDPOINTS/<UBEX_EP>.MacAddress=<MAC_address>
æ
Example
ç GET /SYS/ENDPOINTS/UBEX0039A1.MacAddress
æ pr /SYS/ENDPOINTS/UBEX0039A1.MacAddress=A8:D2:36:00:39:DA
Value
Explanation
The endpoint device is set to
Transmitter
Transmitter. See the details in the
Transmitter Mode
section.
The endpoint device is set to Receiver.
Receiver
See the details in the
Receiver Mode
section.
The endpoint device is set to
Transceiver
Transceiver. See the details in the
Transceiver Mode
section.
109