10. Firmware Upgrade
10. Firmware Upgrade
Type the following commands for setting a static IP address:
ç SET
/MEDIA/DEVICEMAP/<logical_device_ID>/MNT/MANAGEMENT/NETWORK.StaticIpAddress=<IP>
ç CALL /MEDIA/DEVICEMAP/<logical_device_ID>/MNT/MANAGEMENT/NETWORK:applySettings()
The
<logical_device_ID>
parameter is the ID of the endpoint device, for example: X1, X2, X3, etc. The
parameter is the IP address which are wanted to be set on the endpoint device.
Example:
ç SET /MEDIA/DEVICEMAP/X1/MNT/MANAGEMENT/NETWORK.StaticIpAddress=192.168.0.53
ç CALL /MEDIA/DEVICEMAP/X1/MNT/MANAGEMENT/NETWORK:applySettings()
ATTENTION!

Make sure that all endpoint devices have different static IP addresses or the dynamic IP address
(DHCP) is enabled in them to avoid the IP conflict.
Repeat the procedure with all endpoint devices which are wanted to be upgraded.
Step 4 - Set All Endpoints to Bootload (Service / Firmware Upgrade) Mode.
Two possible methods are for completing it:
via using LW3 protocol commands;
via front panel LCD menu.
Via Using LW3 Protocol Commands
Connect to the MMU using a terminal application (e.g. Putty) or use the built-in Terminal of the LDC software
/ Built-in web. See more details in the
Terminal Window
Type the following commands to set the device to bootload mode:
ç CALL /MEDIA/DEVICEMAP/<logical_device_ID>:bootload()
The
<logical_device_ID>
parameter is the ID of the endpoint device, for example: X1, X2, X3, etc. The
parameter is the IP address which are wanted to be set on the endpoint device.
The device reboots and starts in bootload (service / firmware upgrade) mode.
Example:
ç CALL /MEDIA/DEVICEMAP/X1:bootload()
Repeat the procedure with all endpoint devices which are wanted to be upgraded.
Via Front Panel LCD Menu
Navigate to the System settings menu and select the Bootload mode option. Select
Yes at the confirmation. The device reboots and starts in bootload (service /
firmware upgrade) mode.
Applied F-series endpoint firmware package: v1.4.1 | Applied R-series endpoint firmware package: v1.4.1 | Applied MMU firmware package: v1.2.1 | LDC software: v1.34.0b2
UBEX series – Matrix Application Mode – User's Manual
UBEX series – Matrix Application Mode – User's Manual
<IP>
section.
<IP>
BOOTLOAD MODE
Are you sure you
want to enter
bootload mode?
No
Yes
10.6.2. Start the LDU2 Application and Follow the Steps
Discovering the Devices
After launching LDU2 the device discovery an empty window appears. Click on the Search for devices button
to start finding the Lightware devices on the network.
Device discovery is in progress in LDU2