Sending Hex Codes In Big-Endian Format Via Ir Port; Centralized Firmware Upgrade; Query The Status Of Firmware Update - Lightware UBEX Series User Manual

Matrix application mode, av over ip multimedia extender
Table of Contents

Advertisement

 
 
9. Programmer's Reference
9. Programmer's Reference
9.21.5. Sending Hex Codes in Big-endian Format via IR Port
Command and Response
ç CALL·/MEDIA/CONTROL/IR/<out>/PORT:sendProntoHexBigEndian(<hex_code>)
æ mO·/MEDIA/CONTROL/IR/<out>/PORT:sendProntoHexBigEndian
Parameters
Identifier
Parameter description
<hex_code>
Pronto hex format code
INFO:

This command can send exactly one pronto hex message. The header of the IR code contains the
length of the whole code in hexa format. If the code is deficient or duplicated, it causes syntax error.
Example
ç CALL /MEDIA/CONTROL/IR/D101/PORT:sendProntoHexBigEndian(0000006d0025000300a900a80015
003f0015003f0015003f00150015001500150015001500150015001500150015003f0015003f00150
03f00150015001500150015001500150015001500150015003f0015003f0015 003f00150015001500
150015001500150015001500150015001 500150015001500150015003f0015003f0015003f001500
3f0015 003f0015070200a900a80015001500150e6e)
æ mO //MEDIA/CONTROL/IR/D101/PORT:sendProntoHexBigEndian
Learning Raw IR Code with a Terminal Program
Step 1. Connect to the endpoint device with a terminal program.
Step 2. Push the desired button of the remote control to scan the raw IR code.
Step 3. Remove all the non-hexadecimal characters (e.g. spaces, h characters etc.) from the code.
The pronto hex code which learned by a Lightware device is big-endian format.
Applied F-series endpoint firmware package: v1.4.1 | Applied R-series endpoint firmware package: v1.4.1 | Applied MMU firmware package: v1.2.1 | LDC software: v1.34.0b2
UBEX series – Matrix Application Mode – User's Manual
UBEX series – Matrix Application Mode – User's Manual
Parameter values
Accepts
maximum
765
character-long
code
hexadecimal format (0-9; A-F; a-f) without space
character in big-endian system.
9.22. Centralized Firmware Upgrade

ATTENTION!
The centralized firmware upgrade feature is working from the installed MMU firmware v1.1.0
and endpoint firmware v1.3.1 and available for the later firmware package versions. The endpoint firmware
packages till v1.3.1 can be installed with LDU2 software - see the details in the
Method
section.
See the details about this feature and the steps of the upgrade with the Lightware Device Controller (LDC)
software in the
Endpoint Upgrade - Centralized Firmware Upgrade
Based on the centralized firmware upgrade method the firmware package of the Matrix Management Unit
in
(MMU) contains the firmware packages of the endpoint devices either. Thus, the firmware packages are
released in pairs which are developed and tested together. See the table showing which version of endpoint
firmware belongs the firmware package of the MMU in the
Parameters
Parameter
<UBEX_EP>
9.22.1. Query the Status of Firmware Update
Command and Response
ç GET•/SYS/ENDPOINTS/<UBEX_EP>.FirmwareUpdateStatus
pr•/SYS/ENDPOINTS/<UBEX_EP>.FirmwareUpdateStatus=<status>
æ
Parameters
Identifier
Parameter description
The firmware update
<status>
status of the connected
endpoint devices
Example
ç GET /SYS/ENDPOINTS/UBEX0039A1.FirmwareUpdateStatus
æ pr /SYS/ENDPOINTS/UBEX0039A1.FirmwareUpdateStatus=OutOfDate
section.
Endpoint Firmware Packages in the MMU
Description
Formula
UBEX endpoint ID
UBEX<last_6_characters_of_the_MAC_address>
Value
The status is unknown. Please check
the claiming status of the endpoint, see
N/A
the details in the
Status of an Endpoint
The firmware of the device is up to
UpToDate
date.
The firmware of the device is out of
OutOfDate
date.
UpdateInProgress
The firmware update is in progress.
The firmware update procedure is
UpdateCancelled
cancelled.
149
149
Endpoint Upgrade - Manual
section.
Explanation
Query the Claiming
section.

Advertisement

Table of Contents
loading