9. Programmer's Reference
9. Programmer's Reference
9.18.2. Databits Setting
Command and Response
SET•/MANAGEMENT/CONTROL/SERIAL/<port>.DataBits=<databits>
ç
pw•/MANAGEMENT/CONTROL/SERIAL/<port>.DataBits=<databits>
æ
Parameters
The
<databits>
of the selected port can be set to the following values: 7, 8.
Example
ç SET /MANAGEMENT/CONTROL/SERIAL/P1.DataBits=8
æ pw /MANAGEMENT/CONTROL/SERIAL/P1.DataBits=8
9.18.3. Stopbits Setting
Command and Response
SET•/MANAGEMENT/CONTROL/SERIAL/<port>.StopBits=<stopbits>
ç
pw•/MANAGEMENT/CONTROL/SERIAL/<port>.StopBits=<stopbits>
æ
Parameters
The
<stopbits>
of the selected port can be set to the following values: 1, 2.
Example
ç SET /MANAGEMENT/CONTROL/SERIAL/P1.StopBits=2
æ pw /MANAGEMENT/CONTROL/SERIAL/P1.StopBits=2
9.18.4. Parity Setting
Command and Response
SET•/MANAGEMENT/CONTROL/SERIAL/<port>.Parity=<parity>
ç
pw•/MANAGEMENT/CONTROL/SERIAL/<port>.Parity=<parity>
æ
Parameters
The
<stopbits>
of the selected port can be set to the following values: None, Odd, Even, Mark, Space.
Example
ç SET /MANAGEMENT/CONTROL/SERIAL/P1.Parity=Even
æ pw /MANAGEMENT/CONTROL/SERIAL/P1.Parity=Even
Applied F-series endpoint firmware package: v1.4.1 | Applied R-series endpoint firmware package: v1.4.1 | Applied MMU firmware package: v1.2.1 | LDC software: v1.34.0b2
UBEX series – Matrix Application Mode – User's Manual
UBEX series – Matrix Application Mode – User's Manual
9.18.5. Enabling the Port
Command and Response
SET•/MANAGEMENT/CONTROL/SERIAL/<port>.Enabled=<logical_value>
ç
pw•/MANAGEMENT/CONTROL/SERIAL/<port>.Enabled=<logical_value>
æ
Parameters
The
<logical_value>
Example
ç SET /MANAGEMENT/CONTROL/SERIAL/P1.Enabled=true
æ pw /MANAGEMENT/CONTROL/SERIAL/P1.Enabled=true
9.19. Serial Port Configuration - Endpoint Devices
DIFFERENCE:

Only the UBEX-PRO20-HDMI-F110 endpoint model is built with RS-232 port.
9.19.1. BAUD Rate Setting
Command and Response
SET•/MEDIA/CONTROL/UART/<port>/PORT.Baudrate=<number>
ç
pw•/MEDIA/CONTROL/UART/<port>/PORT.Baudrate=<number>
æ
Parameters
Identifier
<number>
Example
ç SET /MEDIA/CONTROL/UART/P101/PORT.Baudrate=7
æ pw /MEDIA/CONTROL/UART/P101/PORT.Baudrate=7
#rs232 #rs-232 #serial
can be true or false.
Parameter description
Value
0
1
2
3
Baud rate value
4
5
6
7
143
143
Explanation
4800
7200
9600
14400
19200
38400
57600
115200