9. Programmer's Reference
9. Programmer's Reference
9.9.14. Query the Timing Mode
The query returns with the current status of the timing mode. See more details about it in the
section.
Command and Response
#timingmode #freerun #sourcelocked
ç GET•/MEDIA/STREAMS/VIDEO/<out>/PORT.TimingMode
pr•/MEDIA/STREAMS/VIDEO/<out>/PORT.TimingMode=<timing_mode>
æ
Parameters
The
<timing_mode>
can be Freerun or SourceLocked.
Example
ç GET /MEDIA/STREAMS/VIDEO/D101/STREAM.TimingMode
æ pr /MEDIA/STREAMS/VIDEO/D101/STREAM.TimingMode=SourceLocked
9.9.15. Timing Mode Setting
The timing mode is set with the following command. See more details about it in the
Command and Response
SET•/MEDIA/STREAMS/VIDEO/<out>/PORT.TimingModeSetting=<timing_mode>
ç
pw•/MEDIA/STREAMS/VIDEO/<out>/PORT.TimingModeSetting=<timing_mode>
æ
Parameters
The
<timing_mode>
can be set to Freerun or SourceLocked.
Example
ç SET /MEDIA/STREAMS/VIDEO/D202/PORT.TimingModeSetting=SourceLocked
æ pw /MEDIA/STREAMS/VIDEO/D202/PORT.TimingModeSetting=SourceLocked
Applied F-series endpoint firmware package: v1.4.1 | Applied R-series endpoint firmware package: v1.4.1 | Applied MMU firmware package: v1.2.1 | LDC software: v1.34.0b2
UBEX series – Matrix Application Mode – User's Manual
UBEX series – Matrix Application Mode – User's Manual
9.9.16. No Sync Screen (Test Pattern) Mode
Timing Modes
The No sync screen feature generates an image which can be displayed when no incoming signal on the
port. The following method turns on or off the Test Pattern function:
Command and Response
SET•/MEDIA/STREAMS/VIDEO/<out>/PORT.NoSyncMode=<nosync_mode>
ç
æ pw•/MEDIA/STREAMS/VIDEO/<out>/PORT.
Parameters
<nosync_mode>
Timing Modes
section.
Example
ç SET /MEDIA/STREAMS/VIDEO/D1002/PORT.NoSyncMode=NoSignal
æ pw /MEDIA/STREAMS/VIDEO/D1002/PORT.NoSyncMode=NoSignal
9.9.17. No Sync Screen (Test Pattern) Color Setting
The No sync screen feature generates an image which can be displayed when there is no incoming signal on
the port. The following method sets the displayed color defined in RGB code.
Command and Response
SET•/MEDIA/STREAMS/VIDEO/<out>/PORT.NoSyncColor=<RGB_code>
ç
æ pw•/MEDIA/STREAMS/VIDEO/<out>/PORT.
Example
ç SET /MEDIA/STREAMS/VIDEO/D901/PORT.NoSyncColor=128,128,128
æ pw /MEDIA/STREAMS/VIDEO/D901/PORT.NoSyncColor=128,128,128
#testpattern #nosyncscreen
NoSyncMode=<nosync_mode>
Identifier
Parameter description
Value
AlwaysOff
Test pattern mode
NoSignal
setting
AlwaysOn
NoSyncColor=<RGB_code>
120
120
Explanation
The test pattern is not displayed on the
output.
The test pattern is displayed if there is no
video is received on the output port.
The test pattern is displayed on the output
even there is an incoming signal.