9. Programmer's Reference
9. Programmer's Reference
9.20. Infrared Port Configuration - Endpoint Devices
DIFFERENCE:
Only the UBEX-PRO20-HDMI-F110 endpoint model is built with IR input/output ports.
Parameters
#infra #ir
Parameter
<in>
IR input port, example: S101
<out>
IR output port, example: D101
9.20.1. Enable/Disable the Port
Command and Response
SET•/MEDIA/CONTROL/IR/<in|out>.Enabled=<logical_value>
ç
pw•/MEDIA/CONTROL/IR/<in|out>.Enabled=<logical_value>
æ
Parameters
Identifier
Parameter description
Port enable/disable
<logical_value>
setting
Example
ç SET /MEDIA/CONTROL/IR/S101.Enable=true
æ pw /MEDIA/CONTROL/IR/S101.Enable=true
9.20.2. Setting the Name of the Input Port
Command and Response
SET•/MEDIA/CONTROL/IR/<in>.SourceName=<name>
ç
pw•/MEDIA/CONTROL/IR/<in>.SourceName=<name>
æ
Example
ç SET /MEDIA/CONTROL/IR/S101.SourceName=Emitter_TV
æ pw /MEDIA/CONTROL/IR/S101.SourceName=Emitter_TV
Applied F-series endpoint firmware package: v1.4.1 | Applied R-series endpoint firmware package: v1.4.1 | Applied MMU firmware package: v1.2.1 | LDC software: v1.34.0b2
UBEX series – Matrix Application Mode – User's Manual
UBEX series – Matrix Application Mode – User's Manual
Description
Value
Explanation
true
The port is enabled.
false
The port is disabled.
9.20.3. Setting the Name of the Output Port
Command and Response
SET•/MEDIA/CONTROL/IR/<out>.DestinationName=<name>
ç
pw•/MEDIA/CONTROL/IR/<out>.DestinationName=<name>
æ
Example
ç SET /MEDIA/CONTROL/IR/D101.DestinationName=Detector_MeetingRoom1
æ pw /MEDIA/CONTROL/IR/D101.DestinationName=Detector_MeetingRoom1
9.20.4. Change Command Injection Port Number
Command and Response
SET·/MEDIA/CONTROL/IR/<in|out>.ServerPort=<port_no>
ç
pw·/MEDIA/CONTROL/IR/<in|out>.ServerPort=<port_no>
æ
Example
ç SET /MEDIA/CONTROL/IR/D101.CommandInjectionPort=9001
æ pw /MEDIA/CONTROL/IR/D101.CommandInjectionPort=9001
9.20.5. Enable/Disable Output Signal Modulation
Command and Response
SET·/MEDIA/CONTROL/IR/<out>/PORT.EnableModulation=<logical_value>
ç
pw·/MEDIA/CONTROL/IR/<out>/PORT.EnableModulation=<logical_value>
æ
Parameters
Identifier
Parameter description
Signal modulation enable/
<logical_value>
disable setting
Example
ç SET /MEDIA/CONTROL/IR/D101/PORT.EnableModulation=false
æ pw /MEDIA/CONTROL/IR/D101/PORT.EnableModulation=false
INFO:
The default setting value is true (enabled).
146
146
Value
Explanation
true
The signal modulation is enabled.
false