Change The Gateway Address (Static); Apply Network Settings; Ethernet Port Configuration - Endpoint; Enabling The Port - Lightware UBEX Series User Manual

Matrix application mode, av over ip multimedia extender
Table of Contents

Advertisement

 
 
9. Programmer's Reference
9. Programmer's Reference
9.16.8. Change the Gateway Address (Static)
Command and Response
SET•/MANAGEMENT/NETWORK.StaticGatewayAddress=<gw_address>
ç
pw•/MANAGEMENT/NETWORK.StaticGatewayAddress=<gw_address>
æ
Example
ç SET /MANAGEMENT/NETWORK.StaticGatewayAddress=192.168.0.1
æ pw /MANAGEMENT/NETWORK.StaticGatewayAddress=192.168.0.1
9.16.9. Apply Network Settings
Command and Response
ç CALL•/MANAGEMENT/NETWORK:ApplySettings()
æ mO•/MANAGEMENT/NETWORK:ApplySettings
Example
ç CALL /MANAGEMENT/NETWORK:ApplySettings()
æ mO /MANAGEMENT/NETWORK:ApplySettings
All changed network settings are applied and the control network interface is going to be restarted.
9.17. Ethernet Port Configuration - Endpoint
9.17.1. Enabling the Port
Command and Response
SET•/MEDIA/CONTROL/ETHERNET/<port>/PORT.Enabled=<logical_value>
ç
pw•/MEDIA/CONTROL/ETHERNET/<port>/PORT.Enabled=<logical_value>
æ
Parameters
The
<logical_value>
can be true or false.
Example
ç SET /MEDIA/CONTROL/ETHERNET/P101/PORT.Enabled=true
æ pw /MEDIA/CONTROL/ETHERNET/P101/PORT.Enabled=true
#ethernet
Applied F-series endpoint firmware package: v1.4.1 | Applied R-series endpoint firmware package: v1.4.1 | Applied MMU firmware package: v1.2.1 | LDC software: v1.34.0b2
UBEX series – Matrix Application Mode – User's Manual
UBEX series – Matrix Application Mode – User's Manual
9.17.2. Ethernet Mode Setting
Command and Response
SET•/MEDIA/CONTROL/ETHERNET/<port>/PORT.Mode=<mode>
ç
pw•/MEDIA/CONTROL/ETHERNET/<port>/PORT.Mode=<mode>
æ
Parameters
Identifier
<mode>
Example
ç SET /MEDIA/CONTROL/ETHERNET/P102/PORT.Mode=0
æ pw /MEDIA/CONTROL/ETHERNET/P102/PORT.Mode=0
9.17.3. Setting the Name of the Port
Command and Response
SET•/MEDIA/CONTROL/ETHERNET/<port>.Name=<name>
ç
pw•/MEDIA/CONTROL/ETHERNET/<port>.Name=<name>
æ
Example
ç SET /MEDIA/CONTROL/ETHERNET/P103.Name=My_PC
æ pw /MEDIA/CONTROL/ETHERNET/P103.Name=My_PC
9.17.4. Query the Tags of the Port
The query returns with the tags which are added by the user.
Command and Response
ç GET•/MEDIA/CONTROL/ETHERNET/<port>.Tags
pr•/MEDIA/CONTROL/ETHERNET/<port>.Tags=<tag>
æ
Example
ç GET /MEDIA/CONTROL/ETHERNET/P101.Tags
æ pr /MEDIA/CONTROL/ETHERNET/P101.Tags=PC;100Mbps
Parameter description
Value
0
Autonegotiation
1
10Mbps half-duplex
Setting of
2
10Mbps full-duplex
autonegotiation or
manual speed and
3
100Mbps half-duplex
duplexity
4
100Mbps full-duplex
5
1000Mbps full-duplex
#tag