8.3.7 Registering/Executing control commands

External devices that are connected to the MSD can be controlled by registering commands to the following
buttons:
・ "Standby" button
・ "Input channel selection" button
・ "COMMAND" buttons
・ "DISPLAY POWER" button
No control commands are registered by default.
To execute a control command that is registered to a "COMMAND" button:
1. Press the "UNLOCK" button.
2. The registered "COMMAND" buttons light green.
3. Select and press the desired button.
To execute a control command that is registered to the "DISPLAY POWER" button:
1. Press the "DISPLAY POWER" button.
2. The "DISPLAY POWER" button blinks amber while the command is being executed.
3. After POWER ON command is executed, the button lights amber.
After POWER OFF command is executed, the button turns off.
Commands for controlling the MSD
Execution conditions for control
commands
Communication ports for control
commands
44
[Fig. 8.13] Buttons for control commands
[Table 8.4] Control command registration
UP to 32 commands
Up to 40 conditions
RS-232C, IN5's RS-232C, OUT C's RS-232C,
Internal loop back,
LAN connections 1 to 8
【See: 9.16 Control command】