9.15.6 LAN operation mode

Menu
Top→LAN SETTINGS→COMMUNICATION MODE
Setting for
CONNECTION1 to CONNECTION8
Setting value
Items
Operation mode
Destination IP address
PJLink protocol
connection
Destination connection
*1
number
PJLink protocol
*2
password
*1
For PJLink protocol connections, the target port number is fixed at "4352".
*2
For PJLink protocol connections, the maximum permissible number of characters is 32.
If you do not want password authentication, you do not have set a password.
You can set the LAN operation mode to either "RECEIVER" mode that controls the MSD externally or
"TRANSMITTER" mode that controls peripheral devices from the MSD.
If you select "TRANSMITTER" mode, you need to set the parameters to support the connected device that will
be controlled.
Press the "MENU/ENTER" button to apply the setting.

9.15.7 HDBaseT LAN

Menu
Top→LAN SETTINGS→HDBT COMMUNICATION
Setting for
IN5, OUT C
Setting value
ON [Default], OFF
You can enable/disable the LAN capabilities of each HDBaseT I/O connector.
132
[Table 9.33] LAN operation mode
Receiver mode
RECEIVER [Default]
N/A
N/A
N/A
N/A
Setting value
Transmitter mode
TRANSMITTER
0.0.0.0 to 255.255.255.255
[Default] 192.168.1.198
ON : Use
OFF: Not use [Default]
1 to 65535 [Default] 1100
20, 30 to 39, 41 to 5A, 61 to 7A in ASCII
code (in hex) [Default] 20 (space)
【See: 9.15 LAN】