3.3.13 Control commands

@EXC
Setting
Command
Response
Parameter
Setting
Command
example
Response
Description Executing COMMAND 1→2→3 in order.
Setting
Command
example
Response
Description Executing COMMAND 6.
Remarks
@GDS / @SDS
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description
Setting
Command
example
Response
Description
Remarks
Executing control commands
@EXC, command_1 (, command_2・・・)
@EXC, command_1 (, command_2・・・)
command_1-5: Control command
1 = COMMAND 1 to 32 = COMMAND 32
@EXC,1,2,3
@EXC,1,2,3
@EXC,6
@EXC,6,RECV: POWER OFF
If a command to display received data is executed, the received result is returned.
In this example, "POWER OFF" is received from the target device.
Since the result is returned after control command execution is complete, it
sometimes may take a time for response.
Power button of sink device
@GDS
@GDS, onoff_1, onoff_2, onoff_3, onoff_4
@SDS, ch_1, onoff_1 (, ch_2, onoff_2・・・)
@SDS, ch_1, onoff_1 (, ch_2, onoff_2・・・)
onoff_1-4: Power button of sink device
0 = OFF, 1 = ON
ch_1-4: Output channel
0 = All outputs, 1 = OUT1 to 4 = OUT4
@GDS
@GDS,1,1,1,1
Getting the power button status of sink device.
OUT1, OUT2, OUT3, and OUT4: powered ON
@SDS,1,1
@SDS,1,1
Setting the power button of the sink device that is connected OUT1 to ON.
Since the result is returned after control command execution is complete, it
sometimes may take a time for response.