9.16.1 Registering/Editing control command

Menu
Top→CONTROL COMMAND→COMMAND REGISTER/EDIT
Setting for
CMD 1 to CMD32
Setting value
[Table 9.34] Setting control command
You can register and edit up to 32 control commands.
Press the "MENU/ENTER" button to apply the setting.
Setting item
COM
PORT
yes
COM SIZE
yes
DELAY
yes
Communication
yes
port
COMMAND
yes
INPUT MODE
Send command
yes
data
[Table 9.34] Setting control command
CC
CEC
yes
yes
Select "COM", "CC" or "CEC".
no
no
Set the number of bytes to be sent
starting with the first byte.
yes
yes
Set the waiting time to issue control
commands. Use this item for devices
such as projectors that requires time to
cool down after powering off.
no
no
Set the following communication ports to
"OFF" (not sending communication
commands) or "ON" (sending
communication commands).
Those ports can be set separately, and
communication commands can be sent to
multiple communication ports at the same
time.
- RS1
- RS2
- OUTC RS
- IN5 RS
- LOOP BAC
- LAN1 to LAN8 : LAN connection 1 to 8
no
no
Set the input mode of send command
data. Select "ASCII" if "DATA" of
"COMMAND" consists of only 0A, 0D, and
20 to 7D of ASCII codes.
Select "HEX" if "DATA" of "COMMAND"
includes other codes.
no
no
Set the command from the first byte
according to the number of bytes set in
"COM SIZE" (up to 30 bytes).
Description
*5
: RS-232C (CH1)
*5
: RS-232C (CH2)
: OUT C RS-232C
: IN5 RS-232C
: Internal loop back
*6
MSD-701AMP User Guide
Range
COM : Communication
command [Default]
CC
: Contact closure
CEC
: HDMI CEC control
0BYTE to 30BYTE
[Default] 0BYTE
0ms to 999s999ms
[Default] 0ms
OFF
: Not sending reply
command [Default]
ON
: Sending reply
command
ASCII [Default]
HEX
0A, 0D, 20 to 7D in ASCII,
00 to FF in hex
[Default] 20 (space)