Automatic Setting Of Input Timing; Initializing Digital Input Timing - IDK MSD-701AMP User Manual

Digital multi switcher with integrated audio power amplifier
Table of Contents

Advertisement

MSD-701AMP User Guide

9.8.8 Automatic setting of input timing

Menu
Top→INPUT TIMING→UNREGISTERED SIGNAL
Setting value
AUTO SETUP ON [Default], AUTO SETUP OFF
The MSD recalls the optimal table from the library of built-in tables and sets the input timing automatically.
However, if unregistered analog signals are input, the input timing must be set. By setting this menu feature to
"AUTO SETUP ON", automatic measurement is executed and the input timing is set automatically if analog
signals that cannot be detected by the MSD are being introduces to a particular input for the first time.
Note:
If automatic measurement results in aspect ratio inconsistencies, set the following menus:
・ 9.8.2 The total number of horizontal pixels
・ 9.8.3 Horizontal start position
・ 9.8.4 Horizontal active area
・ 9.8.5 Vertical start position
・ 9.8.6 Vertical active area

9.8.9 Initializing digital input timing

Menu
Top→INPUT TIMING→INPUT TIMING INIT.
Setting for
IN1 to IN5, IN6 (Digital), IN7 (Digital) for each input signal
Use this menu to restore default input timing.
Press the "MENU/ENTER" button to apply the setting.
If no signal is input, "NOT AVAILABLE NOW" will appear on the front display.
98
【See: 9.8.1 Automatic measurement】