Automatic Measurement Of Start Position - IDK MSD-701AMP User Manual

Digital multi switcher with integrated audio power amplifier
Table of Contents

Advertisement

9.8.7 Automatic measurement of start position

Menu
Top→INPUT TIMING→START POSITION DETECT.
Setting for
IN6 (Analog), IN7 (Analog) for each input signal
Setting value
ALL OFF : Not measuring all inputs from the input automatically
OFF
ON
PCs usually output video signals meeting the VESA standard, but some PCs output cut-off (a few dots from
the VESA standard) signals. In such a case, if the video is output using the video format table in the MSD, the
left edge may not be displayed or black line may be output.
If you set this menu to "ON", the MSD continually monitors analog input signals to identify the upper left
portion of the image and then automatically adjusts formatting to place the image correctly on the display.
If no signal is input, "NOT AVAILABLE NOW" will appear on the front display.
Notes:
・ For motion images, some content may not be displayed full screen, and the image position may be moved
each time the automatic setting measurement is applied. In such a case, set this menu to "OFF". As "OFF"
and "ON" are saved for each input signal, it can be set according to the input signal. If you do not want this
function for any resolution format, select "ALL OFF".
・ Only the start position is set by the automatic measurement feature listed in this menu.
If the total number of horizontal pixels and active area do not match, the lower right may be cut off or
blackout may be output. In this case, adjust the whole screen by following automatic measurement. As the
set value must not exceed the value set in start position, some video formats may be displayed with
blackouts at the left side or top of the image.
・ This menu can be set only if "[Fig. 9.14] Conditions of automatic measurement" is satisfactory.
・ Even if you set this menu feature to "ON", manual settings will be applied and the automatic measurement
is not executed if you set any of the following menus: the total number of horizontal pixels, start position,
and active area. If you set tracking, the manual setting is applied, and tracking is not set automatically
when the automatic measurement is executed. When you execute automatic measurement, setting values
or this menu will be valid again.
: Not measuring the current input signal automatically
: Measuring the current input signal automatically [Default]
【See: 9.8.1 Automatic measurement】
【See: 9.8.2 The total number of horizontal pixels】
【See: 9.8.3 Horizontal start position, 9.8.4 Horizontal active area】
【See: 9.8.5 Vertical start position, 9.8.6 Vertical active area】
【See: 9.8.12 Tracking】
MSD-701AMP User Guide
97

Advertisement

Table of Contents
loading

Table of Contents