7.4.4 Contact closure

The MSD has a total of six independently controlled contact closure channels for external control.
Each connector supports three channels.
The maximum load is 1 A at 24 VDC per contact.
Connect a cable to the 6-pin captive screw connector, and then insert into the appropriate connector on the
MSD.
28 AWG to 16 AWG conductor gauge is recommended.
The recommended wire strip length is 0.28 in. (7 mm).

7.5 Connecting power cord

Connect the supplied power cord.
[Fig. 7.13] Connecting cable to 6-pin captive screw connector
[Fig. 7.14] Connecting power cord
Up to 0.28" (7mm)
1
2
3
MSD-701AMP User Guide
33