3.3.12 Control commands

@EXC
Setting
Command
Response
Parameter
Setting
Command
example
Response
Description
Setting
Command
example
Response
Description
Remarks
@GDS / @SDS
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description
Setting
Command
example
Response
Description
Remarks
MSD-701UHD / 702UHD / 801UHD/ 802UHD Command Guide
Executing control commands
@EXC, command_1 (, command_2・・・)
@EXC, command_1 (, command_2・・・)
command_1-5: Control command
1 = COMMAND 1 to 32 = COMMAND 32
@EXC,1,2,3
@EXC,1,2,3
Executing COMMAND 1→2→3 in order.
@EXC,6
@EXC,6,RECV:POWER OFF
Executing COMMAND 6.
If a command to display received data is executed, the received result is returned.
In this example, "POWER OFF" is received from the target device.
Since the result is returned after control command execution is complete,
it sometimes may take a time for response.
Power button of sink device
@GDS
@GDS, onoff_1, onoff_2
@SDS, ch_1, onoff_1 (, ch_2, onoff_2)
@SDS, ch_1, onoff_1 (, ch_2, onoff_2)
onoff_1-2: Power button of sink device
0 = OFF, 1 = ON
ch_1-2: Output channel
0 = All outputs, 1 = OUT1, 2 = OUT2
@GDS
@GDS,1,1
Getting the power button status of sink device.
OUT1 and OUT2: powered ON
@SDS,1,1
@SDS,1,1
Setting the power button of the sink device that is connected OUT1 to ON.
Since the result is returned after control command execution is complete,
it sometimes may take a time for response.
81