7.4.3 REMOTE connector

The MSD includes two inputs for controlling MSD's power status and one contact output for controlling
external power distribution unit.
Connect the supplied 8-pin captive screw connector to the MSD.
28 AWG to 16 AWG conductor gauge and a strip length of 0.28 in. (7 mm) are recommended.
Power control
0.28" (7mm)
[Fig. 7.12] Connecting external devices to REMOTE connector
■ REMOTE IN1
Connects to an external button switch to control MSD's power.
+ terminal and – terminal
■ REMOTE IN2
Receives emergency stop signal.
The MSD is powered on if specified voltage (DC 5 V to DC 30 V) is input to + terminal and – terminal.
■ REMOTE OUT (Contact output)
Controls power distribution unit by outputting non-voltage contact signal.
N.C. (Normally Close): Closed during standby
Rated voltage: DC 24 V 1 A
■ REMOTE P
Outputs specified voltage (DC 12 V, 1 KΩ series resistance)
32
Button switch
Switch for receiving
emergency signal
Open (DC 5 V): Standby
N.O. (Normally Open): Opened during standby
Contact output
REMOTE connector
Supplied captive screw connector
Power distribution
unit
Close (0.5 mA): Power ON
【See: 9.17.1 Power control mode】