IDEC MICROSmart FC6A Series Ladder Programming Manual page 76

Automation organizer windldr
Hide thumbs Also See for MICROSmart FC6A Series:
Table of Contents

Advertisement

2: D
EVICES
Bit
14
13
12
15
Upper
Status
Lower
Expansion Module Connection Information
Reserved
Number of Connected
Expansion Modules
Upper Lower
D8598, D8599 = Expansion Interface Remote Slave Module (Unit 1) Slot Information
D8600, D8601 = Expansion Interface Remote Slave Module (Unit 2) Slot Information
D8602, D8603 = Expansion Interface Remote Slave Module (Unit 3) Slot Information
D8604, D8605 = Expansion Interface Remote Slave Module (Unit 4) Slot Information
D8606, D8607 = Expansion Interface Remote Slave Module (Unit 5) Slot Information
D8608, D8609 = Expansion Interface Remote Slave Module (Unit 6) Slot Information
D8610, D8611 = Expansion Interface Remote Slave Module (Unit 7) Slot Information
D8612, D8613 = Expansion Interface Remote Slave Module (Unit 8) Slot Information
D8614, D8615 = Expansion Interface Remote Slave Module (Unit 9) Slot Information
D8616, D8617 = Expansion Interface Remote Slave Module (Unit 10) Slot Information
The system software version displays the version of the software written to the device.
For details on the type ID and status, see "List of Type IDs and Status" on page 2-46.
■ D8618: Refresh Time of Expansion Interface Remote Master/Slave Modules Current Value
The current value of the I/O refresh time of the expansion modules connected with the expansion interface remote master/slave
modules is stored in increments of 1 ms.
■ D8619: Refresh Time of Expansion Interface Remote Master/Slave Modules Maximum Value
The maximum value of the I/O refresh time of the expansion modules connected with the expansion interface remote master/
slave modules is stored in increments of 1 ms.
■ D8630: CPU Module Ethernet Port 2 IP Settings/DNS Settings Switching
The IP settings/DNS settings for Ethernet Port 2 can be changed by writing one of the setting values in the following table to
D8630 and then turning on M8333.
To use this function, enable Enable D8630 (IP Settings / DNS Settings switching) on Ethernet Port 2 in Function Area
Settings of WindLDR.
The meanings of the setting values are as follows.
Setting Value
0
1
2
■ D8631 to D8634: CPU Module Ethernet Port 2 IP Address (Write-only)
These registers are used to write the IP address of Ethernet port 2 on the Plus CPU module.
IP address: To set as aaa.bbb.ccc.ddd, write the following.
D8631 = aaa, D8632 = bbb, D8633 = ccc, D8634 = ddd
■ D8635 to D8638: CPU Module Ethernet Port 2 Subnet Mask (Write-only)
These registers are used to write the subnet mask of Ethernet port 2 on the Plus CPU module.
Subnet mask: For aaa.bbb.ccc.ddd, write the following.
D8635 = aaa, D8636 = bbb, D8637 = ccc, D8638 = ddd
2-44
Bit
Bit
11
10
9
6
5
8
7
System Software Version
(0 to 15)
Conform to function area settings.
Enable DHCP.
Conform to special data register (D8631 to D8650) settings.
FC6A S
MICROS
ERIES
Bit
4
3
2
1
0
Type ID
IP Settings/DNS Settings
L
P
MART
ADDER
ROGRAMMING
M
FC9Y-B1726
ANUAL