3. S1 (source 1): Control register
S1 specifies the first data register of the data registers to use with PULS1, PULS2, PULS3, or PULS4 instructions.
Starting from the specified data register, 8 consecutive data registers are used.
Specify the first data register so that the device range is not exceeded.
The operation mode and pulse frequency settings differ by the CPU module type and the instruction.
Storage
destination
Output pulse
Starting number+0
frequency
(high word)
Output pulse
Starting number+1
frequency
(low word)
Preset value
Starting number+2
(high word)
Preset value
Starting number+3
(low word)
Current value
Starting number+4
(high word)
Current value
Starting number+5
(low word)
Starting number+6
Error status
Starting number+7
Reserved
*1 The upper and lower data registers change according to the 32-bit data storage method specified.
For details, see "32-bit Data Storage" on page 3-9.
4. S2 (source 2): Initialization Input
S2 specifies the initialization input. When the initialization input is turned on, the initial values configured in the WindLDR PULS
dialog box, on the Settings tab, are stored in the control registers. An external input or an internal relay can be specified.
When the initialization input is on, the initial values are written to the data registers with each scan. (Even when the PULS
instruction is not executed (when not on), if the initialization input is turned on, the initial values are stored in the data
registers.) To only initialize the values one time, use the initialization input in combination with the SOTU (single output up)
instruction or the SOTD (single output down) instruction.
5. D1 (destination 1): Operation Status
D1 specifies the first internal relay of the internal relays that store the operation status.
Starting from the specified internal relay, 3 sequential internal relays are used.
Specify the first internal relay so that the device range is not exceeded.
Storage
Function
Destination
Starting
Pulse output ON
number+0
Starting
Pulse output
number+1
complete
Starting
Overflow
number+2
Function
All-in-One CPU Module
PULS1, PULS2:
15 to 100,000
*1
(increments of 1 Hz)
PULS3, PULS4:
15 to 5,000
*1
(increments of 1 Hz)
*1
1 to 100,000,000 pulses
*1
*1
1 to 100,000,000 pulses
*1
0 to 4
0: Pulse output OFF
1: Pulse output ON
0: Pulse output not complete
1: Pulse output complete
0: None
1: An overflow has occurred
FC6A S
MICROS
ERIES
MART
Setting
CAN J1939 All-in-One CPU
Module/Plus CPU Module
PULS1 to PULS4:
15 to 100,000
(increments of 1 Hz)
Setting
This relay turns on during pulse output.
This relay turns off when pulse output stops.
This relay turns off when the specified number of pulses are output
and output ends.
This relay turns on when pulse output is complete.
This relay turns off when pulse output starts.
When pulse counting is enabled, this relay turns on when a pulse is
output that exceeds the configured preset value.
L
P
M
ADDER
ROGRAMMING
ANUAL
18: P
O
ULSE
UTPUT
Reference
"6. Output pulse frequency" on
page 18-4
"8. Preset value" on page 18-4
"9. Current value" on page 18-4
"10. Error status" on page 18-4
FC9Y-B1726
I
NSTRUCTIONS
18-3