Imov (Indirect Move) - IDEC MICROSmart FC6A Series Ladder Programming Manual

Automation organizer windldr
Hide thumbs Also See for MICROSmart FC6A Series:
Table of Contents

Advertisement

5: M
I
OVE
NSTRUCTIONS

IMOV (Indirect Move)

IMOV(*)
S1(R)
*****
Valid Devices
Device
S1 (Source 1)
S2 (Source 2)
D1 (Destination 1)
D2 (Destination 2)
For valid device address ranges, see "Device Addresses" on page 2-1.
Special internal relays cannot be designated as D1.
When T (timer) or C (counter) is used as S1, S2, or D2, the device data is the timer/counter current value (TC or CC). When T (timer) or C (counter)
is used as D1, the device data is the timer/counter preset value (TP or CP) which can be 0 through 65,535.
When F (float) data is selected, only data register can be designated as S1 or D1.
When F (float) data is selected and S1 does not comply with the normal floating-point format, a user program execution error will result, turning on
special internal relay M8004 and ERR LED on the FC6A Series MICROSmart.
Source device S2 or destination device D2 does not have to be assigned. If S2 or D2 is not assigned, the source or destination device is determined
by S1 or D1 without offset.
Make sure that the source data determined by S1 + S2 and the destination data determined by D1 + D2 are within the valid device range. If the
derived source or destination device exceeds the valid device range, a user program execution error will result, turning on special internal relay
M8004 and the ERR LED on the FC6A Series MICROSmart. For user program execution errors, see "User Program Execution Errors" on page 3-10.
Valid Data Types
W (word)
X
I (integer)
D (double word)
X
L (long)
F (float)
X
5-6
S2
D1(R)
D2
*****
*****
*****
Function
Base address to move from
Offset for S1
Base address to move to
Offset for D1
When S1 (source 1) is a word device and D1 (destination 1) is a Q, M, or R bit device, the data is transferred as
16 points or 32 bits, depending on the data type. When repeat is assigned for a bit device, the quantity of device
bits increases in 16- or 32-point increments.
When a word device such as T (timer), C (counter), or D (data register) is assigned as the source or destination,
1 point (word data) or 2 points (double-word or float data) are used. When repeat is assigned for a word device,
the quantity of device words increases in 1- or 2-point increments.
FC6A S
MICROS
L
ERIES
MART
S1 + S2 → D1 + D2
REP
When input is on, the values contained in devices assigned by S1 and
**
S2 are added together to determine the data source. The 16- or 32-
bit data is then moved to the destination, which is determined by the
sum of values contained in devices assigned by D1 and D2.
I
Q
M
X
X
X
X
X
X
X
X
X
X
P
M
ADDER
ROGRAMMING
ANUAL
R
T
C
D
P
Constant
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
FC9Y-B1726
Repeat
1-99
1-99

Hide quick links:

Advertisement

Table of Contents
loading