IDEC MICROSmart FC6A Series Ladder Programming Manual page 300

Automation organizer windldr
Hide thumbs Also See for MICROSmart FC6A Series:
Table of Contents

Advertisement

18: P
O
I
ULSE
UTPUT
NSTRUCTIONS
■ Settings tab
This tab configures the operation of the PULS instruction.
6.
7.
8.
9.
10.
6. Output pulse frequency
Specifies the pulse frequency. The output frequency error is ±5%.
The setting differs by the CPU module type and the instruction.
CPU Module Type
All-in-One CPU module
CAN J1939 All-in-One CPU module/
Plus CPU module
7. Pulse counting
Enables or disables pulse counting.
If Enable pulse counting is specified, the number of pulses specified by the preset value (8) is output.
If Disable pulse counting is specified, pulses are continuously output while the PULS instruction input is on.
8. Preset value
When the setting for 7. Pulse counting is Enable pulse counting, this setting specifies the number of pulses to output.
9. Current value
Specifies the device (data register) that will store the number of pulses that were output.
The current value is updated when the PULS instruction is executed at each scan.
10. Error status
Outputs the error code that corresponds to the content of an error when there is an error in the settings. If a configuration error
occurs when the PULS instruction input changes from off to on, a user program execution error will occur and error code 20 will
be stored in D8006.
Error
Status
Code
0
Normal
Pulse frequency
2
designation error
Preset value
4
designation error
18-4
Instruction
PULS1, PULS2
PULS3, PULS4
PULS1 to PULS4
All-in-One CPU module
CAN J1939 All-in-One CPU
module/Plus CPU module
If Enable pulse counting is specified, the preset value was not set between 1 and 100,000,000.
FC6A S
MICROS
L
ERIES
MART
Setting Value
15 to 100,000
15 to 5,000
15 to 100,000
Description
PULS1, PULS2:
The pulse frequency was not set between 15 and 100,000.
PULS3, PULS4:
The pulse frequency was not set between 1 and 5,000.
PULS1 to PULS4:
The pulse frequency was not set between 15 and 100,000.
P
M
ADDER
ROGRAMMING
ANUAL
Configurable Range
Frequency
15 Hz to 100 kHz (increments of 1 Hz)
15 Hz to 5 kHz (increments of 1 Hz)
15 Hz to 100 kHz (increments of 1 Hz)
FC9Y-B1726