Deg (Radian To Degree) - IDEC MICROSmart FC6A Series Ladder Programming Manual

Automation organizer windldr
Hide thumbs Also See for MICROSmart FC6A Series:
Table of Contents

Advertisement

21: T
RIGONOMETRIC

DEG (Radian to Degree)

DEG(F)
*****
Valid Devices
Device
S1 (Source 1)
D1 (Destination 1)
For valid device address ranges, see "Device Addresses" on page 2-1.
When the conversion result is not within the range between –3.402823 × 10
38
3.402823 × 10
, special internal relay M8003 (carry or borrow) is turned on except when the conversion result is 0. When the conversion result is
38
below –3.402823 × 10
or over 3.402823 × 10
infinity.
M8003
Execution Result
When the data designated by S1 does not comply with the normal floating-point format, a user program execution error will result, turning on
special internal relay M8004 and ERR LED on the FC6A Series MICROSmart. For details about the user program execution errors, see "User Program
Execution Errors" on page 3-10.
Since the DEG instruction is executed in each scan while input is on, a pulse input from a SOTU or SOTD instruction should be used.
Valid Data Types
W (word)
I (integer)
D (double word)
L (long)
F (float)
X
Example: DEG
DEG(F)
SOTU
I1
21-2
F
I
UNCTION
NSTRUCTIONS
S1·S1+1 rad × 180/
S1
D1
When input is on, the radian value assigned by source device S1 is converted into a degree value
*****
and stored to the destination assigned by device D1.
Function
Radian value to convert into degree
Destination to store conversion results
38
, causing an overflow, the destination device designated by D1 stores a value of minus or plus
Overflow
1
×
38
–3.402823
10
Since floating point data is used, the source and destination devices use two consecutive data registers.
S1
D1
D10
D20
FC6A S
MICROS
ERIES
π
→ D1·D1+1°
I
Q
38
and –1.175495 × 10
Not Zero
0
1
0
1
×
–38
–1.175495
10
0
When input I1 is turned on, the radian value of data registers D10 and D11 assigned by
source device S1 is converted into a degree value and stored to data registers D20 and
D21 assigned by destination device D1.
π
4.712389 rad × 180/
→ 270.0°
S1
4.712389
D10·D11
L
P
MART
ADDER
ROGRAMMING
M
R
T
C
D
P
X
X
–38
or between 1.175495 × 10
0
×
–38
1.175495
10
D20·D21
M
FC9Y-B1726
ANUAL
Constant
Repeat
X
–38
and
Overflow
1
×
38
3.402823
10
D1
270.0