IDEC MICROSmart FC6A Series Ladder Programming Manual page 317

Automation organizer windldr
Hide thumbs Also See for MICROSmart FC6A Series:
Table of Contents

Advertisement

RAMP1 instruction (reversible control disabled) timing chart
RAMP1 instruction, S1 is specified as D0200, D1 is specified as internal relay M0050
RAMP
1
PAMP instruction
input
RAMP instruction input
Pulse frequency
Q0
Pulse output ON
M0050
Pulse output
M0051
complete
Pulse output
M0052
status
When the RAMP instruction input is on, pulses are output according to the settings configured by the control registers. M0050
turns on during pulse output. M0052 turns on or off while increasing or decreasing the pulse frequency. Pulses are output
according to the frequency change time, until they reach the steady pulse frequency (from the initial pulse frequency). When the
frequency change time is specified as 100, the steady pulse frequency is reached in 100 ms by increasing or decreasing the
frequency every 10 ms. Pulse output stops when the pulses configured by the preset value are output. (The number of pulses is
also counted while changing the frequency.) At this time, M0050 turns off and M0051 turns on.
If the RAMP instruction input turns off during pulse output, pulse output is canceled. If the RAMP instruction input turns on again,
the pulse count is reset and pulse counting starts. Even if the contents of the control registers are changed during pulse output,
the change is not reflected in the pulse output operation. The changed content is reflected the next time the RAMP instruction is
executed.
S1
S2
D1
D0200
M0000
M0050
Frequency
change time
FC6A S
MICROS
ERIES
MART
Frequency
change time
L
P
M
ADDER
ROGRAMMING
ANUAL
18: P
O
ULSE
UTPUT
Steady pulse
frequency
Initial pulse
frequency
FC9Y-B1726
I
NSTRUCTIONS
18-21