IDEC MICROSmart FC6A Series Ladder Programming Manual page 324

Automation organizer windldr
Hide thumbs Also See for MICROSmart FC6A Series:
Table of Contents

Advertisement

18: P
O
I
ULSE
UTPUT
NSTRUCTIONS
Settings
■ Device tab
(1)
(1
(1) Select instruction
Selects the RAMPL instruction to use from RAMPL12, RAMPL13, RAMPL14, RAMPL23, RAMPL24, and RAMPL34.
The combination of pulse outputs will depend on the instruction.
For details, see "(11) Reversible control" on page 18-32.
(2) S1 (source 1): Control register
S1 specifies the first data register of the data registers to use with the RAMPL12, RAMPL13, RAMPL14, RAMPL23, RAMPL24,
or RAMPL34 instruction.
Starting from the first data register, 30 continuous words of data registers are used. Specify the first data register so that the
device range is not exceeded.
Storage
Destination
Starting
Combined steady pulse frequency (high word)
number+0
Starting
Combined steady pulse frequency (low word)
number+1
Starting
Combined initial pulse frequency (high word)
number+2
Starting
Combined initial pulse frequency (low word)
number+3
Starting
Frequency change time
number+4
Starting
— Reserved —
number+5
Starting
— Reserved —
number+6
Starting
— Reserved —
number+7
Starting
— Reserved —
number+8
Starting
Error status
number+9
18-28
(2)
(3)
Function
FC6A S
MICROS
L
ERIES
MART
(4)
Setting
*1
15 to 100,000 (increments of 1 Hz)
*1
*1
15 to 100,000 (increments of 1 Hz)
*1
10 to 10,000 (ms)
P
M
ADDER
ROGRAMMING
ANUAL
Reference
"(5) Combined steady pulse
frequency" on page 18-30
"(6) Combined initial pulse
frequency" on page 18-30
"(7) Frequency change time" on
page 18-30
"(8) Error status" on page 18-31
FC9Y-B1726

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents