(8) Error status
Outputs the error code that corresponds to the content of an error when there is an error in the settings. If a configuration
error occurs when the RAMPL instruction input changes from off to on, M8004 (user program execution error) is turned on
and this register is set to the error code.
Error Code
0
Normal
Combined initial pulse
2
frequency designation error
Combined steady pulse
4
frequency designation error
Frequency change time
5
designation error
9
Frequency designation error
X axis initial pulse frequency
12
designation error
X axis preset value
13
designation error
X axis steady pulse
14
frequency designation error
X axis over preset value
18
error
Y axis initial pulse frequency
22
designation error
Y axis preset value
23
designation error
Y axis steady pulse
24
frequency designation error
Y axis over preset value
28
error
*1 Set the combined initial pulse frequency so that it is lower than the combined steady pulse frequency.
*2 The number of pulses in the frequency change area calculated by steady pulse frequency, initial pulse frequency, and frequency
change time has exceed the total number of output pulses. Lower the steady pulse frequency, lower the initial pulse frequency, or
shorten the frequency change time.
■ X-axis Settings tab, Y-axis Settings tab
(9)
(10)
(11)
(12)
(13)
(14)
Status
The combined initial pulse frequency was not set between 15 and 100,000.
The combined steady pulse frequency was not set between 15 and 100,000.
The frequency change time was not set between 10 and 10,000.
The combined initial pulse frequency was set to the same frequency as the combined
steady pulse frequency or it was set to a value larger than the combined steady pulse
*1
frequency.
The X axis initial pulse frequency calculated from the set values was not between 15 and
100,000.
The X axis preset value was not set between -2,147,483,648 and 2,147,483,647 or the
difference between the configured preset value and absolute position counter was
bigger than 100,000,000.
The X axis steady pulse frequency calculated from the set values was not between 15
and 100,000.
The number of X axis pulses when changing the pulse frequency has exceeded the total
number of output pulses.
The Y axis initial pulse frequency calculated from the set values was not between 15 and
100,000.
The Y axis preset value was not set between -2,147,483,648 and 2,147,483,647 or the
difference between the configured preset value and absolute position counter was
bigger than 100,000,000.
The Y axis steady pulse frequency calculated from the set values was not between 15
and 100,000.
The number of Y axis pulses when changing the pulse frequency has exceeded the total
number of output pulses.
FC6A S
MICROS
ERIES
MART
Description
*2
*2
L
P
M
ADDER
ROGRAMMING
ANUAL
18: P
O
ULSE
UTPUT
FC9Y-B1726
I
NSTRUCTIONS
18-31