IDEC MICROSmart FC6A Series Ladder Programming Manual page 563

Automation organizer windldr
Hide thumbs Also See for MICROSmart FC6A Series:
Table of Contents

Advertisement

Operation Example
Configuration Example
Devices tag
Item
S1 (flow rate)
S2 (enable totalizer input)
S3 (log execution input)
D1 (status)
D2 (logged data)
Settings tag
Item
Flow rate unit
Sampling period
Max quantity of logged data
Example program
SCALE(W)
S1
1
D8058
M0000
FLWA
S1
1
D0010
M0000
WEEK
M0000
Description
D0010
The value of the analog input value converted to the flow rate.
M0050
M0100
WEEK instruction output. Set to turn on for one scan every day at 00:00.
D0150
D0200
Description
Second
0.1 sec
10
S2
S3
D1
D2
D0000
M8120
D0010
M0030
S2
S3
D1
D2
M0050
M0100
D0150
D0200
S1
S2
S3
D1
1
M0100
FC6A S
MICROS
ERIES
MART
27: F
• If input M0000 turns on, the result of analog input value D8058 being
converted to the flow rate is stored in D0010 with each scan.
• Sampling of the flow rate D0010 and totalization starts by turning on
input M0000 and enable totalizer input M0050.
• The operation status is stored in D1 (status).
• By turning on M0100 for one scan every day at 00:00 with the WEEK
instruction, S3 (log execution input) turns on and the current log
information is stored in D2 (logged data).
L
P
M
ADDER
ROGRAMMING
ANUAL
C
LOW
ALCULATION
Comments
Comments
FC9Y-B1726
I
NSTRUCTIONS
27-17

Hide quick links:

Advertisement

Table of Contents
loading