6. S4 (source 4): Origin Input
S4 specifies the origin signal. The rise in the origin signal is detected and pulse output is stopped. An external input or an
internal relay can be specified. When ZRN mode 0 is selected for 9. Zero return method, the origin signal is ignored, even when
specified.
Detection Speed
High-speed
Normal
Notes:
Do not use the same input or internal relay as the origin signal for the ZRN1, ZRN2, ZRN3, or ZRN4 instructions.
If they operate simultaneously, pulse output may not stop even if the origin signal changes from on to off.
To use a high-speed origin signal, set the relevant input to Normal Input under Special Inputs on Function Area Settings. Do not use
the input as interrupt input, catch input, high-speed counter, or frequency measurement.
When using a high-speed origin signal, ensure that no bounce occurs in the origin signal.
7. D1 (destination 1): Operation Status
D1 specifies the first internal relay of the internal relays that store the operation status.
Starting from the specified relay, 4 sequential relays are used.
Specify the first internal relay so that the device range is not exceeded.
Storage
Destination
Starting number+0
Starting number+1
Starting number+2
Starting number+3
8. D2 (destination 2): Complete Output
D2 specifies the complete signal. When the rise in the complete signal is detected and pulse output is stopped, the complete
signal can be output. An external output or an internal relay can be specified.
This can only be set when ZRN mode 1 is specified for the zero return method. This can be omitted if not using the complete
signal. When ZRN mode 0 is specified, the complete signal is ignored, even when specified.
Note: When an external output (Q0 to Q17) is specified, the complete signal is turned on regardless of the ZRN instruction execution timing with
the ladder and the I/O refresh timing. After the complete signal is turned on, it is reset to off when the ZRN instruction is executed a second time.
ZRN instruction execution timing
ON
Origin signal
OFF
ON
Complete signal
OFF
18-40
Input Device
I0, I1, I3, I4, I6, I7
Inputs except I0, I1, I3,
I4, I6, and I7 and
Internal relays
Function
0: Pulse output OFF
Pulse output ON
1: Pulse output ON
Pulse output
0: Pulse output not complete
complete
1: Pulse output complete
Pulse output
0: Steady pulse output
status
1: Changing output pulse frequency
Zero return
0: Zero return not complete
complete
1: Zero return complete
(1)
(2)
(3)
(4)
FC6A S
MICROS
ERIES
MART
An interrupt is used to read the origin signal.
The origin signal is read without being affected by the user program scan.
The information updated in the END processing is read as the origin signal.
It is affected by the user program scan.
This relay turns on during pulse output. This relay turns
off when ZRN instruction input is turned off or when pulse
output is complete.
This relay turns on when pulse output is complete.
This relay turns off when pulse output starts.
This relay turns on when the pulse output status is
changing.
This relay turns off when the pulse output status is steady.
This relay turns on when the zero return operation is
complete.
This relay turns off when the zero return operation starts.
L
P
M
ADDER
ROGRAMMING
ANUAL
Description
Setting
FC9Y-B1726