IDEC MICROSmart FC6A Series Ladder Programming Manual page 482

Automation organizer windldr
Hide thumbs Also See for MICROSmart FC6A Series:
Table of Contents

Advertisement

25: D
L
I
ATA
OG
NSTRUCTIONS
Notes:
• When the FC6A Series MICROSmart is stopped and then set to run, the header is added and output to the CSV file when the DLOG instruction
is first executed after it starts running. Header output can be selected for the Plus CPU module.
Output example
Time
2015/12/30 08:30:23
Time
2015/12/30 17:30:23
• For details on the SD memory card specification, see Chapter 11 "SD Memory Card" in the "FC6A Series MICROSmart User's Manual".
• For the configuration of the maximum log file size, see Chapter 5 "Functions and Settings" in the "FC6A Series MICROSmart User's Manual".
Notes:
• The number of DLOG instructions that can be programmed in a user program is 48. However, be careful so that the same folders and files are
not specified by DLOG instructions. When the folders are duplicated, log data with a mixed format is output to the same CSV file.
• The DLOG instruction cannot be used in an interrupt program. If used, a user program execution error will result, turning on special internal
relay M8004 and the ERR LED on the FC6A Series MICROSmart. For details about the user program execution errors, see "User Program
Execution Errors" on page 3-10.
• While the input to DLOG instruction is on, log data is repeatedly output to the CSV file. When you want to output the log data only one time,
add a SOTU (single output up instruction) or SOTD (single output down instruction) to the input condition. For SOTU or SOTD, see "SOTU
and SOTD (Single Output Up and Down)" on page 4-28.
• The process of writing data to the SD memory card for the DLOG instruction takes several scans. Once a DLOG instruction is executed, the
process continues until the log data transfer is complete, regardless of any change in the instruction input. While the log data is being written
to the SD memory card, instructions are not being executed, even when the inputs to DLOG instructions are turned on. To execute the DLOG
instruction again, confirm that the previous data transfer process has finished, and then execute the instruction.
Valid Devices
Device
S1 (Source 1)
D1 (Destination 1)
D2 (Destination 2)
Note: Specify the folder name by entering characters.
Special internal relays cannot be designated as D1. Special data registers cannot be designated as D2.
25-2
D0010
Header
12345
Log data
D0020
Appended header
1212
Log data
Function
Folder name (Note)
Completion output
Execution status
FC6A S
MICROS
ERIES
MART
I
Q
M
X
L
P
M
ADDER
ROGRAMMING
ANUAL
R
T
C
D
P
Constant
FC9Y-B1726
Repeat